Friday 16 December 2016

Air conditioner starter switch

Turn on the circuit breaker and furnace switch. The compressor should run and the condenser fan should spin. Key switches and controls to check if your air conditioner or heat pump is not working.


Check each of those safety relays . Control relay switch chattering noises or chattering at contactor switches in air conditioners , heat pumps, water pumps.

We are not professional, this video is for reference only.

Video for Licensed HVAC Professionals ONLY.

Capacitors are small cylindrical objects that store energy. They work with the compressor, the blower motor, and the outside fan in your air conditioner. In air conditioning school, we used to drive out and collect abandoned . They can stop working when the internal switches burn and pit. You need to use an electrical tester to check these.


Saves the expensive gadgets like AC , Motor, Pump from overload , Self Reset . Is it the compressor, fan motor, contactor or capacitor?


This AC stop working and blows hot air. How to fix your AC - Fan kicks on but Compressor Not Working - Replacing run start capacitor. Air conditioning repair CAN BE DANGEROUS so make sure you are familiar with safety precautions before you proceed.


Disclaimer: All power must be shut off and capacitor discharged before repairs are made.


We accept no responsibility for damages to you or your property. These days, electronic relay is also being widely used to disconnect the START winding. This motor is similar to the split-phase motor except that there is an external capacitor . Checking these simple items, switches and controls, including . On trigger side, constant 12v source ( reversed polarity -12v for some reason) whether or not AC switch is on.


Tested pressure sensor on Low side of compressor line with multimeter, continuity checked.


Tested temperature protection switch at compressor, continuity checked. Tried disconnecting battery on . When the weather is hot and everyone is running their air conditioners , the voltage may drop, causing hard start conditions. This is usually an ambient air temperature control that switches the condenser fan from low to high speed as the ambient goes up, usually around 85° to 90°F, when more capacity . There are two common types of motor capacitors, run capacitors and start capacitors.


Many air conditioners and heat pumps have low and high pressure safety switches on them to protect the unit from damage if the system pressure is too low (low refrigerant charge) or.


If your unit is low on charge (I find most often) the safety switch will not allow the unit to start (contactor will not engage). This heat damages the compressor, .

No comments:

Post a Comment

Note: only a member of this blog may post a comment.

Popular Posts