Locked rotor torque formula

The analysis of certain end-winding vibration problems requires an accurate knowledge of the transient currents in an induction motor during the early part of the start-up period where the time rates of change of current are the highest. This paper details the derivation of expressions for the winding currents assuming that the . Helpful tools for calculating motor loads with formulas. The salesman may wish to check the customers specified.


The manufacturer of the motor should have that value.

The locked - rotor torque may vary somewhat with different standstill positions of the rotor with respect to the stator.

Starting torque and locked - rotor torque are the same thing.

The locked rotor torque and current, breakdown torque , pull-up torque and the percent slip, determine the classifications for NEMA design motors. Note that manufacturers will have different characteristics than those defined by NEMA as minimum required values. This is sometimes also referred to as starting torque.


A blocked rotor test is conducted on an induction motor. It is also known as short circuit test, locked rotor test or stalled torque test. From this test, short circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found.


The test is conducted at low voltage . Induction Motor Equivalent Circuit. Determination of Motor Constants. For the rotor locked , s = so that the following equations can be written from the equivalent circuit of.


The formulas and complete calculations are shown below. Alternatively torque can be calculated from the equivalent circuit.


Torque and Power Characteristics. Consequently, starting torque is times the value it would have with. Large motor over current protection is normally set to trip prior to the locked - rotor withstand time (LRWT) . The motor manufacturer shall provide the value of starting voltage requirement and preferred locked - rotor current.


A motor-starting study should be.


To determine this voltage, one must take into account the total line drop to the motor terminals during the high current draw, which is present while the motor is starting. An induction motor can therefore be made without electrical connections to the rotor. Normal line voltage is maintained at the motor terminals.


Application Manual for NEMA Motors.


Both locked torque and locked rotor current vary approximately as the square of the. Electrical - Electrical units, amps and electrical wiring, wire gauge and AWG, electrical formulas and motors . Dual-frequency heat run or coupled heat run. These four parts are detailed as follows.


Locked - Rotor Test at Rated Frequency.