The run capacitor stores charge and delays the current momentarily, which gives the fan rotor time to turn and orient itself so that the induced magnetic force is effective. When the motor is switched on the ohms reading should immediately drop to zero then slowly climb again towards . Use this Motor Trouble-Shooting Chart to diagnose likely causes of motor malfunction such as the motor not starting initially or running then failing restart. Most fans made in recent years use permanent split capacitor motors , as they are efficient and reliable.
However with age capacitors can drift in value.
Electric motor repair and troubleshooting part 3.
What are the main causes of when motor runs and suddenly dies down!
It can be produced by improper power supply or following causes. For slow speeds, stepper motors can be quite useful. Capacitors are electrical components that help create and strengthen the artificial second phase in single-phase electric motors , and always work with the secondary,.