Monday 18 July 2016

Motor base speed

Where: Torque is measured in Lb-Ft. Armature and Field Controlled DC Drives. The motor is armature voltage controlled for constant torque-variable HP operation up to base speed. Above base speed the motor is transferred to field current control . If application requirements are stated in terms of speed regulation within .

And base speed is actually rated name plate speed ,i.

So when ever the speed of motor increases the torque will reduce.

You when the motor starts then the initial torque always high and the speed is zero as. If you are using an inverter, there is no relationship between the DC Buss and the speed except that at sufficient buss voltage, it will work. The electronics in drives are very particular about their internal operation.


The speed at which an induction motor will operate depends on the input power frequency and the number of electrical magnetic poles in the motor. WYE CONN EQ CKT OHMS PER PHASE.


Operation of the motors above rated nameplate speed ( base speed ) is possible, but is limited to conditions that do not require more power than the nameplate rating of the motor. If the minimum or maximum frequency are near or outside the limits mentioned above then the motor manufacturer should be consulted before proceeding. Constant and Variable Torque Speed . Tests show direct- drive extruders are quieter, more energy efficient. Base speed is the nameplate speed , given in RPM, where the motor develops rated horsepower at rated voltage and frequency.


It is an indication of how fast the output shaft will turn the connected equipment when fully loaded with proper voltage and frequency applied.


Very simply, if you drop the frequency, the motor will slow down. Conversely, if you raise the frequency, the motor will speed up. The speed change that will be proportional to the frequency . The above curve suggests that the speed control and braking operation are available from nearly zero speed to above synchronous speed.


V is kept constant above base speed and freq.


Power electronics based variable . It indicates how fast the output shaft will turn the connected equipment when fully loaded and supplied with the proper voltage and frequency. What do all those things on an ac motor nameplate mean. Reversal of direction of rotation of the motor can be obtained by adjusting jockeys of the generator field rheostats.

No comments:

Post a Comment

Note: only a member of this blog may post a comment.

Popular Posts