Across the line motor control diagram

Although “ across-the-line ” motor control circuits are simple and inexpensive, they are not preferred for starting large motors. An alternative to across-the-line motor starting is reduced voltage starting. Identify some of the reasons across-the-line starting is undesirable for large electric motors.


A direct on line (DOL) or across the line starter applies the full line voltage to the motor terminals, the starters or cubicle locations, can usually be found on an ELO drawing.


This is the simplest type of motor starter.

A DOL motor starter also contains protection devices, and in some cases, condition monitoring.

Standard Elementary Diagram Symbols 1.

NEMA and IEC Terminal Markings 4. Control and Power Connections for. Typically, the contactor will be controlled by separate start and stop buttons, and an auxiliary contact on the contactor is use across the start button, as a. Wiring diagrams show the connections to the controller , while line diagrams show circuits of the operation of the controller. Overload Protection protects motors from drawing too much current, overheating, and from literally burning out.


A starter turns an electric motor or. One- line diagram – a diagram that uses.


Across-the-line or Full Voltage . And usually the least expensive). Motors connected across the line are capable of drawing full in- rush . Typical magnetic motor starters that are commonly available include: full voltage ( across-the-line ), reduced voltage, and reversing. As the name implies, a full- voltage or across-the-line magnetic motor starter (Fig.


1) applies full voltage to the motor.


This means the magnetic motor starter is designed to properly handle the . They may be small and similar to the light switches in your home, or they may be much larger dedicated switches designed for control of high amperage circuits. Explanation of three common types of motor starters used in small equipment. EM- RVS -Electro Mechanical Reduced.


RVS - Reduced Voltage Solid State Starters. Magnetic starters are used with larger motors or where remote control is desired (Figure 8-2). A2Series Magnetic Starters are used for full-voltage, across-the-line starting and stopping of squirrel cage motors.


They can be operated locally or remotely by. It comes with optional reversing and e -stop . Our pump panels offer protection against short circuit faults, protection against motor overload faults, and means of .